| STUDY ON OPTIMIZING METHOD OF REDUCING LEAD OXIDATION RATE THROUGH CHEMICAL PHASE ANALYSIS |
|
Received:July 20, 2005
|
| View Full Text View/Add Comment Download reader |
| DOI: |
| KeyWord:Ore; Lead oxidation rate; Chemical phase analysls; Optimizing |
|
| Beijing General Research Institute of Mining and Metallurgy, Beijing 100044, China |
| Hits: 2098 |
| Download times: 21 |
| Abstract: |
| Based on summary and optimization of the conventional analyzing methods, new and more accurate methods were put forward for chemical phase analysis of lead in this paper. 20 % NaCl took the place of 25 % NaCl as the extractant of anglesite, greatly reducing the effect of background on the experiment results; and by using 3% HAC-15% NH4Cl- 1.5% NH2HCl as extractant of lead oxides, making the analysis results more accurate, These methods are of wide application. |
| Close |
|
|
|