ANALYZING THE FAILURE AND IMPROVING METHOD OF THE FOUNDATION BOLT FOR LADLE TURNTABLE
Received:October 30, 2005            
View Full Text  View/Add Comment  Download reader
DOI:
KeyWord:intensity; toughness; brittle failure in this high strength steel. According to analysis paper
Hits: 2106
Download times: 24
Abstract:
      The brittle failure of the foundation bolt for ladle turntable under the static load and low stress happens due to unsuitable between intensity and toughness above, an improving method is proposed for the bolt in this paper.