Experiments on Preparation of 0[sub_s]#[sub_e] Nickel by Vacuum Distillation |
Received:April 06, 2012 Revised:January 30, 2013 |
View Full Text View/Add Comment Download reader |
DOI: |
KeyWord:nickel; vacuum distillation; saturated vapor pressure; vacuum degree |
Author | Institution |
Li Xuepeng |
Institute of Research and Design of YTC |
|
Hits: 1328 |
Download times: 12 |
Abstract: |
1# nickel of which nickel content is 99.96% was treated by vacuum distillation. Saturated vapor pressures of the impurities were calculated under 773K~2023K. And βof some impurities were calculated under certain temperature. Influence of temperature, vacuum degree and time were studied. This 1# nickel was prepared to 0# nickel under the condition: temperature is 1873K, time is 2.5h, and vacuum degree is between 3Pa and 9Pa. |