Determination ofIron Content inLithium#$NBSNickel#$NBSManganese#$NBSCobalt by Inductively Coupled Plasma Mass Spectrometry (ICP-MS)
Received:November 10, 2015   Revised:November 20, 2015   Accepted:November 30, 2015      Published Online:April 28, 2016
View Full Text  View/Add Comment  Download reader
DOI:
KeyWord:ICP-MS; Lithium nickel manganese cobalt ; Iron
        
AuthorInstitution
Yang Chunlin Beijing General Research Institute of Mining and Metallurgy
Su Chunfeng Beijing General Research Institute of Mining and Metallurgy
JingYan Beijing General Research Institute of Mining and Metallurgy
Hits: 2114
Download times: 1
Abstract:
      The method for determinationof iron content in lithium nickel manganese cobalt by inductively coupled plasma mass spectrometry (ICP-MS) was studied. The metallic iron inlithium nickel manganese cobaltwere enriched bya magnetic bar, and digestedin hydrochloric acid. The optimal instrument workingconditions and mass numbers for iron element analysis were selected. The effects of lithium nickel manganese cobalt matrix on the determination were tested. The test results are accurate and reliable. The recoveries of the iron elements were 98.9%-104.1%.