| Experimental research on ozone oxidation treatment of cyanide waste water |
|
Received:March 06, 2017
Revised:March 22, 2017
Accepted:March 23, 2017
Published Online:March 01, 2018
|
| View Full Text View/Add Comment Download reader |
| DOI: |
| KeyWord:cyanide waste water;O3;oxidation;removal rate |
| Author | Institution |
| 彭新平 |
Hunan Nonferrous Metals Research Institute |
| SHEN Yi |
Hunan University of Science and Technology |
| OUYANG Kun |
Hunan Nonferrous Metals Research Institute |
| SHI Shuncun |
Hunan University of Science and Technology |
|
| Hits: 3429 |
| Download times: 1 |
| Abstract: |
| Cyanide waste water was treated by using the O3 oxidation method from a certain gold mine of cyanide residue.Mainly investigated under the condition of same O3 concentration,oxidation reaction time,pH,catalyst,etc factors on cyanide removal effect and the optimum reaction conditions were determined.The results showed that under the conditions of without catalyst,the value was 7.0,reaction time was75min,the removal rate of maximum CN- was 96.3%,and the total CN- was 92.3%. |