| The Statistical Deviation Analysis of Automatic Process Mineralogy |
|
Received:October 27, 2017
Revised:November 08, 2017
Accepted:November 08, 2017
Published Online:July 31, 2018
|
| View Full Text View/Add Comment Download reader |
| DOI: |
| KeyWord:Process mineralogy;MLA;Statistical deviation |
| Author | Institution |
| LI Bo |
Guangdong Institute of Resources Comprehensive Utilization,StateKey Laboratory of Rare Metals Separation and Comprehensive Utilization,The Key Laboratory for Mineral Resources R D and Comprehensive Utilization of Guangdong |
| LIANG Dongyun |
Guangdong Institute of Resources Comprehensive Utilization,StateKey Laboratory of Rare Metals Separation and Comprehensive Utilization,The Key Laboratory for Mineral Resources R D and Comprehensive Utilization of Guangdong |
| ZHANG Lili |
Guangdong Institute of Resources Comprehensive Utilization,StateKey Laboratory of Rare Metals Separation and Comprehensive Utilization,The Key Laboratory for Mineral Resources R D and Comprehensive Utilization of Guangdong |
| HONG Qiuyang |
Guangdong Institute of Resources Comprehensive Utilization,StateKey Laboratory of Rare Metals Separation and Comprehensive Utilization,The Key Laboratory for Mineral Resources R D and Comprehensive Utilization of Guangdong |
| LI Meirong |
Guangdong Institute of Resources Comprehensive Utilization,StateKey Laboratory of Rare Metals Separation and Comprehensive Utilization,The Key Laboratory for Mineral Resources R D and Comprehensive Utilization of Guangdong |
| JIANG Ying |
Guangdong Institute of Resources Comprehensive Utilization,StateKey Laboratory of Rare Metals Separation and Comprehensive Utilization,The Key Laboratory for Mineral Resources R D and Comprehensive Utilization of Guangdong |
|
| Hits: 4137 |
| Download times: 2482 |
| Abstract: |
| A mathematical model of volume percentage of mineral(p), statistic(n)and relative error(E) in MLA analysis is proposed by simplified hypothesis.The measurement error can be estimated by given volume percentage of the target minerals, statistical number of particles and confidence level.Four kinds of pure minerals are formulated as the sample with known composition,to verify measurement accuracy of automatic mineralogy system.The experimental results show that when the statistic become larger,the measured values of different minerals get closer to the theoretical value.On the other hand,when the statistic become less,the measured value deviate even furtherSfrom the theoretical value,which lead to increased statistical error.We can achieve to accurately measure process mineralogy parameters of different grade ores by selecting large particles number. |
| Close |
|
|
|