| Bismuth-bearing copper concentrate Leaching separation test |
|
Received:March 16, 2018
Revised:March 16, 2018
Accepted:March 20, 2018
Published Online:May 13, 2019
|
| View Full Text View/Add Comment Download reader |
| DOI: |
| KeyWord:Bismuth-bearing copper concentrate;Leaching;neutralization;copper concentrate;Bismuth oxychloride |
| Author | Institution |
| ZHAO Feng |
BGRIMM Technology Group |
| WANG Sheng-dong |
BGRIMM Technology Group |
| FENG Lin-yong |
BGRIMM Technology Group |
| JIANG Xun-xiong |
BGRIMM Technology Group |
| Zhang Deng-gao |
BGRIMM Technology Group |
| Liu Wei |
BGRIMM Technology Group |
|
| Hits: 2457 |
| Download times: 1490 |
| Abstract: |
| A process of leaching with hydrochloric acid and Ferric chloride hexahydrate was adopted to separate copper and bismuth from Bismuth-bearing copper concentrate. Results showed that `the optimal parameters for separating copper and bismuth are HCl 2mol/L,FeCl3.6H2O 320g/kg ore,liquid-to-solid ratio 3:1,temperature 90℃,retention time 3h. The leaching recovery of bismuth is greater than 95%,the content of bismuth is from 2.97% to 0.2% in copper concentrate in line with the industry standard. Neutralization test was conducted with leach liquor to get bismuth oxychloride product which contain bismuth is more than 65%. |