| Optimization and Improvement of High Impurity Copper Removal Electro-deposition Production |
|
Received:September 11, 2020
Revised:November 01, 2020
Accepted:November 02, 2020
Published Online:May 13, 2021
|
| View Full Text View/Add Comment Download reader |
| DOI: |
| KeyWord:De-copper electro deposition; Cell voltage; Copper arsenic ratio; High impurity |
| Author | Institution |
| CHAI Xing–Liang |
Copper Branch Company of Yunnan Tin Company Limited,Gejiu;China;Faculty of Metallurgical and Energy Engineering,Kunming University of Science and Technology,Kunming,;China |
| CHEN Ya-ting |
Copper Branch Company of Yunnan Tin Company Limited,Gejiu |
| JIANG Wen–bing |
Copper Branch Company of Yunnan Tin Company Limited,Gejiu |
| YUAN Hai–bin |
Copper Branch Company of Yunnan Tin Company Limited,Gejiu |
|
| Hits: 1558 |
| Download times: 918 |
| Abstract: |
| ABSTRACT: In this paper, the production experiment was carried out from several main factors affecting the power consumption of copper stripping electro deposition, such as cell voltage, copper arsenic ratio, temperature, operation period, etc, under the technological conditions of copper 20-38 g/L, arsenic 10-19 g/L and nickel 20-27 g/L, the average cell voltage of electro deposition is reduced from 2.9 V to 2.2 V, the ratio of copper to arsenic is reduced from 2.1 to 1.4, the temperature of electrolyte is controlled at 50-55℃, the production cycle is controlled within 5-7 days, and the power consumption of de copper electro-deposition is reduced 10.71%. |